2014

E-assay concept: detection of bisphenol A with a label-free electrochemical competitive immunoassay.

Biosensors & bioelectronics Wang X, Reisberg S, Serradji N, Anquetin G, Pham MC, Wu W, Dong CZ, Piro B
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

A label-free electrochemical immunosensor was developed by electropolymerization of N-(3-(4-(2-(4-hydroxyphenyl)propan-2-yl)phenoxy)propyl) 3-(5-hydroxy-1,4-dihydro-1,4-dioxonaphthalen-2(3)-yl)propionamide (JugBPA). By combination with an antibody directed to bisphenol A (αBPA), this conducting polymer-based biosensor can detect BPA directly with a limit of detection of 2pgmL(-1). Square wave voltammetry shows that the polymer film presents a current decrease upon anti-BPA binding and an opposite current increase upon BPA addition in solution. This electrochemical immunosensor (E-assay) also shows high selectivity towards closely related compounds (bisphenol A dimethacrylate, and dibutyl phthalate). The E-assay concept described here could be a promising tool for simple, low-cost and reagentless on-site environmental monitoring.

关键词