2014

Self-powered biosensor for ascorbic acid with a Prussian blue electrochromic display.

Biosensors & bioelectronics Zloczewska A, Celebanska A, Szot K, Tomaszewska D, Opallo M, Jönsson-Niedziolka M
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

We report on the development of a nanocarbon based anode for sensing of ascorbic acid (AA). The oxidation of AA on this anode occurs at a quite low overpotential which enables the anode to be connected to a biocathode to form an ascorbic acid/O2 biofuel cell that functions as a self-powered biosensor. In conjunction with a Prussian blue electrochromic display the anode can also work as a truly self-powered sensor. The oxidation of ascorbic acid at the anode leads to a reduction of the Prussian blue in the display. The reduced form of Prussian blue, called Prussian white, is transparent. The rate of change from blue to colourless is dependent on the concentration of ascorbic acid. The display can easily be regenerated by connecting it to the biocathode which returns the Prussian blue to its oxidized form. In this way we have created the first self-powered electrochromic sensor that gives quantitative information about the analyte concentration. This is demonstrated by measuring the concentration of ascorbic acid in orange juice. The reported quantitative read-out electrochromic display can serve as a template for the creation of cheap, miniturizable sensors for other relevant analytes.

关键词