2014

A label-free electrochemiluminescence aptasensor for thrombin detection based on host-guest recognition between tris(bipyridine)ruthenium(II)-β-cyclodextrin and aptamer.

Biosensors & bioelectronics Chen Q, Chen H, Zhao Y, Zhang F, Yang F, Tang J, He P
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

An ultrasensitive label-free electrochemiluminescence (ECL) aptasensor for the detection of thrombin was developed based on the specific recognition between tris(bipyridine)ruthenium(II)-β-cyclodextrin (tris(bpyRu)-β-CD) and the anti-thrombin aptamer (aptamer). The NH2-aptamer was first immobilized on the activated glassy carbon electrode (GCE) by coupling interaction. By use of the specific recognition between tris(bpyRu)-β-CD and aptamer, tris(bpyRu)-β-CD was then attached on the surface of GCE. Resulting from the outstanding photoactive properties of tris(bpyRu)-β-CD, the fabricated GCE performed strong ECL signal with the coreactant of 2-(dibutylamino)ethanol (DBAE). However, in the presence of thrombin, aptamer-thrombin bioaffinity complexes were formed, which restricted the recognition activities between aptamer and tris(bpyRu)-β-CD. Thus, fewer tris(bpyRu)-β-CD could be attached on the surface of GCE and led to an obvious decrease of ECL signal. Fortunately, the difference of ECL intensity before and after combination with thrombin was logarithmically linear with the concentration of thrombin in a wide range of 10 nM-1 pM. Meantime, a detection limit of 0.1 pM without any other signal labeling or amplifying procedures indicated that the biosensor performed excellent sensitivity, operability and simplicity.

关键词