2014

Biosensing platform based on graphene oxide via self-assembly induced by synergic interactions.

Analytical biochemistry Tian J, Yuan PX, Shan D, Ding SN, Zhang GY, Zhang XJ
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

A novel self-assembled glucose biosensor based on graphene oxide (GO) was constructed by using 1-pyrenebutyric acid-N-hydroxysuccinimide ester (PANHS) as linking molecular. The stepwise self-assembly process was performed for PANHS anchoring in N,N-dimethylformamide (DMF) solvent and the further glucose oxidase (GOD) binding in aqueous solution, respectively. The molecular interactions and the morphologic properties were characterized by Fourier transform infrared spectroscopy (FTIR), field emission scanning electronic microscopy (FESEM), and atomic force microscopy (AFM). In addition, the quantitative loadings of anchored PANHS and GOD were well elucidated by surface plasmon resonance (SPR) measurements. The obtained novel glucose sensor exhibited satisfactory analytical performance to glucose: wide linear range (4.0×10(-6) to 4.4×10(-3) M), fast response (10s), high sensitivity (40.5±0.4 mA M(-1) cm(-2)), and low detection limit (2 μM, S/N=3). Furthermore, the biosensor exhibited excellent long-term stability and satisfactory reproducibility.