One-step, ultrasensitive, and electrochemical assay of microRNAs based on T7 exonuclease assisted cyclic enzymatic amplification.

Analytical chemistry Wang M, Fu Z, Li B, Zhou Y, Yin H, Ai S
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

Taking advantage of the special exodeoxyribonuclease activity of T7 exonuclease, a simple, sensitive, selective, and label-free microRNA biosensor based on the cyclic enzymatic amplification method (CEAM) has been proposed. First, thiol functionalized DNA probes were assembled onto a gold nanoparticles modified gold electrode surface through a Au-S bond, followed by hybridizing with target miRNA. Subsequently, DNA in RNA/DNA duplexes was digested by T7 exonuclease, which can release the microRNA molecules from the electrode surface and return into the buffer solution. Meanwhile, the released microRNA can further hybridize with the unhybridized DNA probes on the modified electrode surface. On the basis of it, an isothermal amplification cycle is realized. The T7 exonuclease-assisted CEAM achieved a low detection limit of 0.17 fM. Moreover, this assay presents excellent specificity with discriminating only a single-base mismatched microRNA sequence. Furthermore, this work can also be applied to detect avian leukemia based on the decreased expression level of microRNA-21.