2014

Metal mesh device sensor immobilized with a trimethoxysilane-containing glycopolymer for label-free detection of proteins and bacteria.

ACS applied materials & interfaces Seto H, Kamba S, Kondo T, Hasegawa M, Nashima S, Ehara Y, Ogawa Y, Hoshino Y, Miura Y
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

Biosensors for the detection of proteins and bacteria have been developed using glycopolymer-immobilized metal mesh devices. The trimethoxysilane-containing glycopolymer was immobilized onto a metal mesh device using the silane coupling reaction. The surface shape and transmittance properties of the original metal mesh device were maintained following the immobilization of the glycopolymer. The mannose-binding protein (concanavalin A) could be detected at concentrations in the range of 10(-9) to 10(-6) mol L(-1) using the glycopolymer-immobilized metal mesh device sensor, whereas another protein (bovine serum albumin) was not detected. A detection limit of 1 ng mm(-2) was achieved for the amount of adsorbed concanavalin A. The glycopolymer-immobilized metal mesh device sensor could also detect bacteria as well as protein. The mannose-binding strain of Escherichia coli was specifically detected by the glycopolymer-immobilized metal mesh device sensor. The glycopolymer-immobilized metal mesh device could therefore be used as a label-free biosensor showing high levels of selectivity and sensitivity toward proteins and bacteria.

关键词