2015

Electrochemiluminescence biosensor for ultrasensitive determination of ochratoxin A in corn samples based on aptamer and hyperbranched rolling circle amplification.

Biosensors & bioelectronics Yang L, Zhang Y, Li R, Lin C, Guo L, Qiu B, Lin Z, Chen G
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

Determination of ochratoxin A (OTA) is highly important for food safety control. In this study, a signal-on electrochemiluminescence (ECL) biosensor which combined the characteristics of high efficiency of hyperbranched rolling circle amplification (HRCA) and high selectivity of aptamer was developed for OTA determination. The capture probe DNA (CDNA) was firstly immobilized on the gold electrode surface through Au-S interaction, then the OTA aptamer was modified on the electrode surface through hybridization with CDNA. Since OTA can competitively bind with the aptamer due to their high affinity, which would induce the releasing of aptamer from the electrode surface. Subsequently, the free CDNA on the electrode surface can hybridize with the padlock probe and induce HRCA reaction subsequently. Thus, the HRCA products which contained large amount of double-stranded DNA (dsDNA) fragments can be accumulated on the electrode surface. Since Ru(phen)3(2+) can intercalate into the groove of dsDNA and acts as ECL indicator, high ECL intensity can be detected from the electrode surface. The enhanced ECL intensity has a linear relationship with OTA in the range of 0.05-500 pg/mL with a correlation coefficient of 0.9957, and the limit of detection (LOD) was 0.02 pg/mL. The developed biosensor has been applied to determine OTA concentration in the corn samples with satisfied results.

关键词