2015

Cyclic voltammetric acetylcholinesterase biosensor for the detection of captan in apple samples with the aid of chemometrics.

Analytical and bioanalytical chemistry Nesakumar N, Sethuraman S, Krishnan UM, Rayappan JB
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

The presence of captan residues in apples shows high toxicity, which often causes eye and skin irritation, dermatitis, conjunctivitis, and vomiting in humans. In this context, an electrochemical biosensor based on acetylcholinesterase (AChE) immobilized on a ZnO nanorod interface has been proposed. In this work, Hill, dose-response, and first-, second-, and third-order polynomial regression models were successfully applied and the prediction ability of these models was tested with the use of current density obtained from the cyclic voltammograms of appropriate captan solutions. The Pt/ZnO/AChE bioelectrode showed a high sensitivity of 0.538 μA cm(-2) μM(-1) in the linear range from 0.05 to 25.0 μM with a limit of detection of 107 nM. The recovery results were observed between 98.4 and 102.4 % from the apple sample. This work provides a new promising tool for the detection of captan in apple samples.

关键词