2015

Colorimetric monitoring of rolling circle amplification for detection of H5N1 influenza virus using metal indicator.

Biosensors & bioelectronics Hamidi SV, Ghourchian H
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

A new colorimetric method for monitoring of rolling circle amplification was developed. At first H5N1 target hybrids with padlock probe (PLP) and then PLP is circularized upon the action of T4 ligase enzyme. Subsequently, the circular probe is served as a template for hyperbranched rolling circle amplification (HRCA) by utilizing Bst DNA polymerase enzyme. By improving the reaction, pyrophosphate is produced via DNA polymerization and chelates the Mg(2+) in the buffer solution. This causes change in solution color in the presence of hydroxy naphthol blue (HNB) as a metal indicator. By using pH shock instead of heat shock and isothermal RCA reaction not only the procedure becomes easier, but also application of HNB for colorimetric detection of RCA reaction further simplifies the assay. The responses of the biosensor toward H5N1 were linear in the concentration range from 0.16 to 1.20 pM with a detection limit of 28 fM.

关键词