2015

B cells Using Calcium Signaling for Specific and Rapid Detection of Escherichia coli O157:H7.

Scientific reports Wang L, Wang R, Kong BW, Jin S, Ye K, Fang W, Li Y
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

A rapid and sensitive detection technology is highly desirable for specific detection of E. coli O157:H7, one of the leading bacterial pathogens causing foodborne illness. In this study, we reported the rapid detection of E. coli O157:H7 by using calcium signaling of the B cell upon cellular membrane anchors anti-E. coli O157:H7 IgM. The binding of E. coli O157:H7 to the IgM on B cell surface activates the B cell receptor (BCR)-induced Ca(2+) signaling pathway and results in the release of Ca(2+) within seconds. The elevated intracellular Ca(2+) triggers Fura-2, a fluorescent Ca(2+) indicator, for reporting the presence of pathogens. The Fura-2 is transferred to B cells before detection. The study demonstrated that the developed B cell based biosensor was able to specifically detect E. coli O157:H7 at the low concentration within 10 min in pure culture samples. Finally, the B cell based biosensor was used for the detection of E. coli O157:H7 in ground beef samples. With its short detection time and high sensitivity at the low concentration of the target bacteria, this B cell biosensor shows promise in future application of the high throughput and rapid food detection, biosafety and environmental monitoring.

关键词