2015

Tyrosinase conjugated reduced graphene oxide based biointerface for bisphenol A sensor.

Biosensors & bioelectronics Reza KK, Ali MA, Srivastava S, Agrawal VV, Biradar AM
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

We have fabricated a nanocomposite of reduced graphene oxide (rGO) sheets and chitosan (Cn) polymer based highly sensitive electrochemical biosensor for detection of bisphenol A (BPA). The two-dimensional structure and chemical functionality of rGO and Cn provide an excellent electrode surface for loading of tyrosinase enzyme molecules. This rGO-Cn nanocomposite is capable of effectively utilizing their superior conductivity, larger effective surface area and superior electrochemical performance due to its synergistic effect between rGO and Cn. The structural, morphological and electrochemical characterizations of nanocomposite sheets have been performed by electron microscopy, X-ray diffraction, FTIR and Potentiostat/Galvanostat techniques. This fabricated biosensor is sensitive to nanomolar (0.74 nM) concentration of BPA and detection time is 10s compared to conventional BPA ELISA kit (0.3 µg/L and 2.5h). The rGO-Cn based biosensor exhibits a higher sensitivity (83.3 µA nM(-1) cm(-2)), wider linearity (0.01-50 µM) with good selectivity towards BPA. This biosensor is capable to quantify real sample of BPA using packaged drinking water bottles. This rGO-Cn nanocomposite sheets emerges as a potential electrode material for detection of other estrogenic substrate.

关键词