2016

Influence of immobilization strategies on biosensing response characteristics: A comparative study.

Enzyme and microbial technology Kaur G, Saha S, Tomar M, Gupta V
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

The immobilization technique plays an important role in fabrication of a biosensor. NiO based cholesterol biosensor has been used to study the effect of various immobilization techniques on the biosensing response characteristics. The biosensors were fabricated by immobilizing cholesterol oxidase on NiO thin films by three different immobilization techniques viz. physisorption, cross-linking and covalent binding. The study reveals a strong dependence of biosensing response on corresponding immobilization technique. The biosensor based on immobilization by covalent bonding shows superior response characteristics as compared to others owing to its zero length. The results highlight the significance of immobilization technique for biosensor fabrication.

关键词