2016

Development of a highly specific and sensitive cadmium and lead microbial biosensor using synthetic CadC-T7 genetic circuitry.

Biosensors & bioelectronics Kim HJ, Lim JW, Jeong H, Lee SJ, Lee DW, Kim T, Lee SJ
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

Multiple copies of a cadC homolog encoding a heavy metal-responsive transcription factor were found in the genome of a bacterium isolated from ocean sediment, and the heavy metal responses of the encoded proteins were characterized using a fluorescence reporter assay. Each CadC regulator exhibited distinct specificity in response to heavy metal ions, indicating their potential use as modular heavy metal biosensors. Next, we constructed CadC-controlled T7 RNA transcription systems for intracellular signal amplification, i.e., higher sensitivity. Flow cytometry revealed that cadmium and lead ions could be recognized specifically by CadC-T7 biosensors, which could be combined with a microfluidic platform to generate heavy metal biosensor devices with increased sensitivity. Our results demonstrate the successful development of synthetic CadC-T7 genetic circuitry for use in improved heavy metal biosensor microfluidic devices.

关键词