2016

Porous silicon membrane-modified electrodes for label-free voltammetric detection of MS2 bacteriophage.

Biosensors & bioelectronics Reta N, Michelmore A, Saint C, Prieto-Simón B, Voelcker NH
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

A proof of concept for the label-free detection of bacteriophage MS2, a model indicator of microbiological contamination, is validated in this work as a porous silicon (pSi) membrane-based electrochemical biosensor. PSi membranes were used to afford nanochannel architectures. The sensing mechanism was based on the nanochannel blockage caused by MS2 binding to immobilized capture antibodies. This blockage was quantified by measuring the oxidation current of the electroactive species reaching the electrode surface, by means of differential pulse voltammetry (DPV). The immunosensor showed a limit of detection of 6 pfu/mL in buffer, allowing the detection of MS2 to levels commonly found in real-world applications, and proved to be unaffected by matrix effects when analyzing MS2 in reservoir water. This platform enables the straightforward, direct and sensitive detection of a broad range of target analytes and constitutes a promising approach towards the development of portable electronic point of sample analysis devices.

关键词