组成图示
示意图生成中
传感器类型
—
检测对象
—
检测原理
—
检测灵敏度
—
效应效果
—
传感器的构成
—
中文摘要
—
英文摘要
In this work, we developed a field effect transistor (FET) biosensor utilizing solution-processed graphene oxide nanoribbon (GONR) for methylene blue (MB) sensing. MB is a unique material; one of its crucial applications is as a marker in the detection of biomaterials. Therefore, a highly sensitive biosensor with a low detection limit that can be fabricated simply in a noncomplex detection scheme is desirable. GONR is made by unzipping multiwall carbon nanotubes, which can be mass-produced at low temperature. The GONR-FET biosensor demonstrated a sensitivity of 12.5μA/mM (determined according to the drain current difference caused by the MB concentration change). The Raman spectra indicate that the materials quality of the GONR and the domain size for the C=C sp2 bonding were both improved after MB detection. X-ray photoelectron spectroscopy revealed that the hydroxyl groups on the GONR were removed by the reductive MB. According to XPS and Raman, the positive charge is proposed to transfer from MB to GONR during sensing. This transfer causes charge in-neutrality in the GONR which is compensated by releasing •OH functional groups. With high sensitivity, a low detection limit, and a simple device structure, the GONR-FET sensor is suitable for sensing biomaterials.