2016

Stable and Reusable Electrochemical Biosensor for Poly(ADP-ribose) Polymerase and Its Inhibitor Based on Enzyme-Initiated Auto-PARylation.

ACS applied materials & interfaces Xu Y, Liu L, Wang Z, Dai Z
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

A stable and reusable electrochemical biosensor for the label-free detection of poly(ADP-ribose) polymerase (PARP) is designed in this work. C-kit-1, a thiol-modified G-quadruplex oligonucleotide, is first self-assembled on a gold electrode surface. The G-quadruplex structure of c-kit-1 can specifically tether and activate PARP, resulting in the generation of negatively charged poly(ADP-ribose) polymer (PAR). On the basis of electrostatic attraction, PAR facilitates the surface accumulation of positively charged electrochemical signal molecules. Through the characterization of electrochemical signal molecules, the label-free quantification of PARP is simply implemented. On the basis of the proposed method, selective quantification of PARP can be achieved over the linear range from 0.01 to 1 U with a calculated detection limit of 0.003U. Further studies also demonstrate the applicability of the proposed method to biosamples revealing the broad potential in practical applications. Furthermore, inhibitor of PARP has also been detected with this biosensor. Meanwhile, benefited from self-assembly on solid surface, this biosensor possesses two important features, i.e., reusability and stability, which are desirable in related biosensors.

关键词