A hybrid system integrating a microbial fuel cell (MFC)-based biosensor with upflow anaerobic sludge blanket (UASB) was investigated for real-time online monitoring of the internal operation of the UASB reactor. The features concerned were its rapidity and steadiness with a constant operation condition. In addition, the signal feedback mechanism was examined by the relationship between voltage and time point of changed COD concentration. The sensitivity of different concentrations was explored by comparing the signal feedback time point between the voltage and pH. Results showed that the electrical signal feedback was more sensitive than pH and the thresholds of sensitivity were S=3×10(-5)V/(mg/L) and S=8×10(-5)V/(mg/L) in different concentration ranges, respectively. Although only 0.94% of the influent COD was translated into electricity and applied for biosensing, this integrated system indicated great potential without additional COD consumption for real-time monitoring.