组成图示
示意图生成中
传感器类型
—
检测对象
—
检测原理
—
检测灵敏度
—
效应效果
—
传感器的构成
—
中文摘要
—
英文摘要
The use of potential mutagenic nitrofuran antibiotic in food animal production has been banned world-wide. Common methods for nitrofuran detection involve complex extraction procedures. In the present study, magnetic beads functionalized with antibody against nitrofuran derivative were used as both the extraction and color developing media in lateral flow biosensor. Derivatization reagent carboxybenzaldehyde is firstly modified with ractopamine. After reaction with nitrofuran metabolites, the resultant molecule has two functional groups: the metabolite moiety and the ractopamine moiety. Metabolite moiety is captured by the antibody that is coated on magnetic beads. This duplex is then loaded onto biosensor and ractopamine moiety is further captured by the antibody immobilized on the test zone of nitrocellulose membrane. Without tedious organic reagent-based extraction procedure, this biosensor was capable of visually detecting four metabolites simultaneously with a detection limit of 0.1 μg/L. No cross-reactivity was observed in the presence of 50 μg/L interferential components. Graphical abstract Derivatization of nitrofuran metabolites (AHD, AOZ, SEM, or AMOZ) and LFA detection of the derivative products.