A label-free aptasensor based on polyethyleneimine wrapped carbon nanotubes in situ formed gold nanoparticles as signal probe for highly sensitive detection of dopamine.

Materials science & engineering. C, Materials for biological applications Azadbakht A, Roushani M, Abbasi AR, Menati S, Derikvand Z
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

Herein, a highly sensitive and selective aptamer biosensor for quantitative detection of a model target, dopamine (DA), was developed by using a gold (Au) electrode modified with highly dispersed gold nanoparticles (AuNPs) and acid-oxidized carbon nanotubes (CNTs-COOH) functionalized with polyethyleneimine (PEI). Amine-terminated12-mercaptureprobe (ssDNA1) as a capture probe and specific DA-aptamer (ssDNA2) as a detection probe was immobilized on the surface of a modified electrode via the formation of covalent amide bond and hybridization, respectively. Methylene blue (MB) was used as the redox probe, which was intercalated into the aptamer through the specific interaction with its guanine bases. In the presence of DA, the interaction between aptamer and DA displaced the MB from the electrode surface, rendering a lowered electrochemical signal attributed to decreased amount of adsorbed MB. The developed electrochemical DA aptasensor showed a good linear response to DA from 5 to 300nM with detection limit of 2.1nM. The biosensor also exhibited satisfactory selectivity and could be successfully used to detect DA in blood serum sample.