2017

High sensitive and selective electrochemical biosensor: Label-free detection of human norovirus using affinity peptide as molecular binder.

Biosensors & bioelectronics Hwang HJ, Ryu MY, Park CY, Ahn J, Park HG, Choi C, Ha SD, Park TJ, Park JP
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

Norovirus is known as the major cause of highly infection for gastrointestinal tracts. In this study, robust and highly sensitive biosensors for detecting human norovirus by employing a recognition affinity peptide-based electrochemical platform were described. A series of amino acid-substituted and cysteine-incorporated recognition peptides isolated from evolutionary phage display technique was chemically synthesized and immobilized to a gold sensor layer, the detection performance of the gold-immobilized synthetic peptide-based sensor system was assessed using QCM, CV and EIS. Using EIS, the limit of detection with Noro-1 as a molecular binder was found to be 99.8nM for recombinant noroviral capsid proteins (rP2) and 7.8copies/mL for human norovirus, thereby demonstrating a high degree of sensitivity for their corresponding targets. These results suggest that a biosensor which consists of affinity peptides as a molecular binder and miniaturized microdevices as diagnostic tool could be served as a new type of biosensing platform for point-of-care testing.

关键词