2017

Nanostructured screen-printed electrodes based on titanate nanowires for biosensing applications.

Materials science & engineering. C, Materials for biological applications Ferraz HC, Machado DF, de Resende NS
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

This work demonstrates the successful modification of screen-printed electrodes using functionalized titanate nanowires for producing a peroxide biosensor. Titanate nanowires were synthesized by the hydrothermal method and characterized using physico-chemical techniques. The surface of the nanowires was modified with (3-aminopropyl)trimethoxysilane and glutaraldehyde to immobilize horseradish peroxidase through covalent bound, obtaining a surface coverage of 1.62mg of enzyme/m2. The surface of screen-printed carbon electrodes was modified with peroxidase-containing nanowires. Cyclic voltammetry and chronoamperometry were employed to study the electrochemical properties of the nanostructured electrode. A low hydrogen peroxide reduction potential around -0.98V (vs Ag, pH7.0) was observed, with linear response in the range of 40 to 560μmolL-1, detection limit of 10.7μmolL-1 and good stability. Reproducibility relative standard deviation was as low as 4.7%. For repeatability, deviation was 3.3%.

关键词