组成图示
示意图生成中
传感器类型
—
检测对象
—
检测原理
—
检测灵敏度
—
效应效果
—
传感器的构成
—
中文摘要
—
英文摘要
This work demonstrates the successful modification of screen-printed electrodes using functionalized titanate nanowires for producing a peroxide biosensor. Titanate nanowires were synthesized by the hydrothermal method and characterized using physico-chemical techniques. The surface of the nanowires was modified with (3-aminopropyl)trimethoxysilane and glutaraldehyde to immobilize horseradish peroxidase through covalent bound, obtaining a surface coverage of 1.62mg of enzyme/m2. The surface of screen-printed carbon electrodes was modified with peroxidase-containing nanowires. Cyclic voltammetry and chronoamperometry were employed to study the electrochemical properties of the nanostructured electrode. A low hydrogen peroxide reduction potential around -0.98V (vs Ag, pH7.0) was observed, with linear response in the range of 40 to 560μmolL-1, detection limit of 10.7μmolL-1 and good stability. Reproducibility relative standard deviation was as low as 4.7%. For repeatability, deviation was 3.3%.