2017

A new lateral flow strip assay (LFSA) using a pair of aptamers for the detection of Vaspin.

Biosensors & bioelectronics Ahmad Raston NH, Nguyen VT, Gu MB
阅读原文 PDF DOI PubMed

组成图示

示意图生成中

传感器类型

检测对象

检测原理

检测灵敏度

效应效果

传感器的构成

中文摘要

英文摘要

A new lateral flow strip assay (LFSA) using a pair of aptamers has been designed and successfully developed using a pair of aptamers-functionalized with gold nanoparticles (AuNPs). This new LFSA biosensor system utilizes a cognate aptamer duo binding to vaspin, a target protein, at the two different binding sites, and exhibited a sensitive and highly selective response to vaspin. A sandwich-type format in LFSA was developed based on biotin-labeled primary V1 aptamer immobilized on streptavidin coated membrane as a capturing probe and secondary V49 aptamer conjugated with AuNPs as a signaling probe. Using this LFSA, vaspin could be visibly observed within the detectable concentrations of vaspin up to 5nM in both buffer and serum conditions. The sensitivity of this LFSA developed in this study was ranged from 0.137 to 25nM in buffer and from 0.105 to 25nM in spiked human serum, respectively. The limit of detection (LOD) of this LFSA was found to be 0.137nM and 0.105nM in buffer and spiked human serum condition, respectively. Therefore, this study has shown successful development of a simple yet effective LFSA for vaspin detection, and this development is not only limited to this target, but also other targets with a pair of aptamers available, without any special and laborious instrumentations. This system will be particularly useful as a screening tool for rapid on-site detection of any targets with a pair of aptamers generated.