Fabrication of an efficient and sensitive colorimetric biosensor based on Uricase/ Th-MOF for uric acid sensing in biological samples.

Biosensors & bioelectronics 2019 Badoei-Dalfard A, Sohrabi N, Karami Z, Sargazi G

本研究报道了一种基于钍基金属有机框架(Th-MOF)人工过氧化物酶的比色生物传感器,用于生物样品中尿酸(UA)检测。Th-MOF 在过氧化氢(H2O2)存在下可催化氧化 3,3',5,5'-四甲基联苯胺(TMB)生成蓝色产物,其催化行为符合 Michaelis–Menten 方程,且对 TMB 的亲和力高于辣根过氧化物酶(HRP)。...

比色生物传感器 尿酸Th-MOF纳米酶尿酸酶

Toxicity assessment of wearable wound sensor constituents on keratinocytes.

Toxicology in vitro : an international journal published in association with BIBRA 2019 Bhushan P, Umasankar Y, Hutcheson JD, Bhansali S

本研究评估可穿戴伤口生物传感器中各组分材料对人角质形成细胞(HaCaT)的细胞毒性,以考察其用于连续伤口监测的生物相容性。研究分别考察金纳米颗粒(Au NPs)、银纳米颗粒(Ag NPs)、尿酸酶(UOx)、二茂铁羧酸(FCA)、多壁碳纳米管(MWCNTs)和聚乙烯醇基聚合物(PVA-SbQ)的单独及混合效应,通过细胞活力、线粒体活...

Uricase grafted nanoconducting matrix based electrochemical biosensor for ultrafast uric acid detection in human serum samples.

International journal of biological macromolecules 2019 Verma S, Choudhary J, Singh KP, Chandra P 等 5 人

本文制备了金纳米粒子修饰还原氧化石墨烯(Au-rGO)纳米复合薄膜,并通过共价固定尿酸酶(UOx)构建电化学生物传感器,用于灵敏、选择性检测尿酸(UA)。差分脉冲伏安法(DPV)结果表明,所制备电极在低电位0.228 V下对UA具有快速响应,在50–800 μM浓度范围内呈线性,灵敏度为86.62±0.19 μA mM−1,检出限为...

An electrochemical biosensor based on novel butylamine capped CZTS nanoparticles immobilized by uricase for uric acid detection.

Biosensors & bioelectronics 2019 Jain S, Verma S, Singh SP, Sharma SN

本文提出一种基于四元铜锌锡硫(Cu2ZnSnS4,CZTS)纳米颗粒薄膜的新型酶基电化学生物传感器,作为制备生物电极的无毒、低成本基质。CZTS 的带隙可通过阳离子比例和纳米颗粒尺寸调节,从而赋予材料所需电学性能。作者采用胶体热注入法合成丁胺封端球形 CZTS 纳米颗粒,粒径约 15–16 nm,带隙为 2.65 eV;通过浸涂法将...