Impedimetric detection of in situ interaction between anti-cancer drug bleomycin and DNA.

International journal of biological macromolecules 2013 Erdem A, Congur G

本文报道了一种基于铅笔石墨电极(PeGE)的电化学阻抗谱(EIS)方法,用于原位监测抗肿瘤药物博来霉素(BLM)与单链 DNA(ssDNA)及双链 DNA(dsDNA)的表面受限相互作用。首先通过电化学预处理和被动吸附将牛胸腺 DNA 固定于 PeGE 表面,随后在含 [Fe(CN)6]3−/4− 氧化还原探针的溶液中记录 Nyqu...

Highly selective electrochemical biosensor for the determination of folic acid based on DNA modified-pencil graphite electrode using response surface methodology.

Materials science & engineering. C, Materials for biological applications 2013 Mirmoghtadaie L, Ensafi AA, Kadivar M, Norouzi P

本文提出一种基于鲑鱼精子双链DNA修饰铅笔石墨电极的电化学生物传感器,用于叶酸快速筛查。首先采用响应面法优化双链DNA在铅笔石墨电极上的固定条件,考察溶液pH、DNA浓度、沉积时间和沉积电位四个因素,各设三个水平。最优条件为pH 4.8、DNA浓度24 μg/mL、沉积时间304 s、沉积电位0.60 V,此时腺嘌呤氧化信号为3.0...

Direct electrochemical sensor for label-free DNA detection based on zero current potentiometry.

Biosensors & bioelectronics 2013 Wu NY, Gao W, He XL, Chang Z 等 5 人