3 条结果 关键词:1,10-菲啰啉-5,6-二酮 ×

Reagent-less amperometric glucose biosensor based on a graphite rod electrode layer-by-layer modified with 1,10-phenanthroline-5,6-dione and glucose oxidase.

Talanta 2017 Kausaite-Minkstimiene A, Simanaityte R, Ramanaviciene A, Glumbokaite L 等 5 人

本文报道了一种可在非搅拌样品溶液中工作的无外加试剂安培葡萄糖生物传感器。工作电极以石墨棒(GR)为基底,将1,10-菲啰啉-5,6-二酮(PD)和葡萄糖氧化酶(GOx)逐层吸附于GR表面,干燥后用戊二醛(GA)蒸气对GOx进行化学交联。优化制备条件为PD负载量12.6 μg、GOx负载量0.24 mg、GA交联25 min。在+20...

Electrochemical biosensor based on glucose oxidase encapsulated within enzymatically synthesized poly(1,10-phenanthroline-5,6-dione).

Colloids and surfaces. B, Biointerfaces 2014 Ciftci H, Oztekin Y, Tamer U, Ramanaviciene A 等 5 人

本研究报道了一种基于葡萄糖氧化酶(GOx)包埋于酶促合成聚(1,10-菲啰啉-5,6-二酮)(pPD)膜中的电化学生物传感器。首先将 GOx 固定于石墨棒(GR)电极表面,并利用 GOx 催化葡萄糖产生的过氧化氢引发 1,10-菲啰啉-5,6-二酮(PD)的氧化聚合,在电极上形成 pPD 包裹层,得到 pPD/GOx/GR 电极。在...

Electrochemical biosensors based on redox carbon nanotubes prepared by noncovalent functionalization with 1,10-phenanthroline-5,6-dione.

The Analyst 2011 Mao X, Wu Y, Xu L, Cao X 等 6 人

为改善碳纳米管对还原型烟酰胺腺嘌呤二核苷酸(NADH)的电催化氧化活性,作者采用非共价功能化方法将氧化还原介体1,10-菲啰啉-5,6-二酮(PD)修饰到多壁碳纳米管/玻碳电极上,构建氧化还原碳纳米管电极PD/CNT/GC。该电极对NADH氧化表现出优异电催化活性,催化反应速率常数kh为7.26×10^3 M^-1 s^-1,在0....