Protein immobilization on 3C-SiC (100) as a substrate for detecting the onset of acute myocardial infarction (AMI).

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference 2012 Oliveros A, Guiseppi-Elie A, Jaroszeski M, Saddow SE

碳化硅(SiC)已被证明具有生物相容性和血液相容性,可作为生物传感器基底材料。本文报道以 3C-SiC 为基底构建用于急性心肌梗死(AMI)早期标志物肌红蛋白(Myoglobin, Myo)检测的生物识别界面。首先通过溶剂清洗、piranha 溶液、HCl 和 HF 处理使 3C-SiC 表面羟基化;随后将样品浸入 1% 3-氨基丙...

电化学生物传感器 碳化硅肌红蛋白抗体固定APTES