10 条结果 关键词:异物反应 ×

A self-cleaning, mechanically robust membrane for minimizing the foreign body reaction: towards extending the lifetime of sub-Q glucose biosensors.

Journal of materials science. Materials in medicine 2019 Means AK, Dong P, Clubb FJ, Friedemann MC 等 8 人

长期皮下植入的连续葡萄糖生物传感器有望改善糖尿病管理并减少相关并发症。然而,固有异物反应(FBR)会改变周围组织局部葡萄糖浓度,并因高代谢炎症细胞募集和致密胶原纤维囊形成而阻碍葡萄糖向传感器扩散。现有减少FBR策略主要依赖聚乙二醇(PEG)等被动抗污材料以降低初始细胞黏附。本文报道一种热响应双网络(DN)膜,利用皮下组织正常温度波动...

Biocompatibility of common implantable sensor materials in a tumor xenograft model.

Journal of biomedical materials research. Part B, Applied biomaterials 2019 Gray ME, Meehan J, Blair EO, Ward C 等 11 人

实时监测肿瘤微环境参数可为肿瘤生物学动态及其治疗反应提供有价值信息,但植入式生物传感器可能因异物反应导致的生物污损而失效。本研究建立了一种新型肿瘤异种移植模型,用于评估六种生物材料(二氧化硅、氮化硅、Parylene-C、Nafion、生物相容性 EPO-TEK 环氧树脂和铂)植入实体瘤后诱发异物反应的潜力。所选材料基于其用于构建一...

Foreign Body Reaction to a Subcutaneously Implanted Self-Cleaning, Thermoresponsive Hydrogel Membrane for Glucose Biosensors.

ACS biomaterials science & engineering 2018 Abraham AA, Means AK, Clubb FJ, Fei R 等 8 人

为实现具有长期功能的皮下植入式葡萄糖生物传感器,本研究评估了一种热响应膜在降低异物反应(FBR)及纤维囊形成方面的能力。FBR的严重程度会降低葡萄糖向传感器的扩散,从而缩短传感器寿命;现有策略多采用聚乙二醇(PEG)等被动抗污材料。作者在啮齿动物中分析了一种皮下植入的“自清洁”圆柱形膜。该膜为热响应双网络纳米复合水凝胶(DNNC),...

Influence of diabetes on the foreign body response to nitric oxide-releasing implants.

Biomaterials 2018 Soto RJ, Merricks EP, Bellinger DA, Nichols TC 等 5 人

本研究比较健康猪与链脲佐菌素诱导糖尿病猪对释放一氧化氮(NO)皮下植入物的异物反应(FBR),评估炎症、胶原包囊和血管生成。钢线基底修饰为不同NO释放动力学的聚氨酯膜,NO通量和持续时间分别为0.8–630.0 pmol cm-2 s-1和2–13 d。植入3、10或25 d后进行组织学与免疫组化分析。糖尿病猪对非NO释放对照植入物...

In vitro and in vivo performance of dexamethasone loaded PLGA microspheres prepared using polymer blends.

International journal of pharmaceutics 2015 Gu B, Wang Y, Burgess DJ

异物反应是植入式葡萄糖生物传感器功能失效和寿命较短的主要原因。维持传感器功能的有效策略是应用可释放药物的生物相容性涂层,以对抗负面组织反应。此前,地塞米松释放的聚乳酸-羟基乙酸共聚物(PLGA)微球嵌入聚乙烯醇(PVA)水凝胶涂层已实现该目标,但传感器寿命取决于涂层中药物释放的持续时间和剂量。为实现长期药物释放,以往采用不同批次微球...

Prevention of foreign body reaction in a pre-clinical large animal model.

Journal of controlled release : official journal of the Controlled Release Society 2015 Kastellorizios M, Papadimitrakopoulos F, Burgess DJ

本研究首次比较小型啮齿类动物(大鼠)与大型动物(小型猪)对小型皮下植入物的异物反应(FBR)。作者将负载地塞米松的聚乳酸-羟基乙酸共聚物(PLGA)微球/聚乙烯醇(PVA)水凝胶复合涂层用于小型皮下植入物,以在哥廷根小型猪模型中预防FBR。植入物由小型硅芯片(模拟小型植入式生物传感器)涂覆复合制剂构成。组织学比较显示,慢性炎症(胶原...

Fabrication of nitric oxide-releasing porous polyurethane membranes-coated needle-type implantable glucose biosensors.

Analytical chemistry 2013 Koh A, Lu Y, Schoenfisch MH

植入式葡萄糖生物传感器组织生物相容性差,主要受异物反应限制。本文结合药物主动释放与多孔传感膜两种策略,制备了一氧化氮(NO)释放型多孔纤维膜修饰的针式葡萄糖生物传感器。采用静电纺丝法将负载NO供体的聚氨酯纤维直接涂覆于针式葡萄糖传感器表面。所得NO释放纤维膜纤维直径为540±139 nm,孔隙率为94.1±3.7%,在6 h内每毫克...

Polymeric "smart" coatings to prevent foreign body response to implantable biosensors.

Journal of controlled release : official journal of the Controlled Release Society 2013 Wang Y, Papadimitrakopoulos F, Burgess DJ

植入式葡萄糖生物传感器用于实时监测时,其性能受传感器-组织界面负面组织反应限制。本研究评估由聚乳酸-羟基乙酸共聚物(PLGA)微球分散于聚乙烯醇(PVA)水凝胶组成的新型聚合物“智能”涂层,并将其与尺寸和功能葡萄糖传感器相同(0.5×0.5×5 mm)的模拟传感器结合,作为可释药生物相容涂层用于植入式生物传感器,以抑制异物反应并提高...

Implantable enzyme amperometric biosensors.

Biosensors & bioelectronics 2012 Kotanen CN, Moussy FG, Carrara S, Guiseppi-Elie A

植入式酶安培生物传感器仍是体内检测、监测和报告与多种病理相关的生化分析物的主要形式。它已广泛用于动物研究,并日益被强调用于糖尿病管理、创伤相关出血管理和重症监护。这些前沿应用要求器件连续留置性能长达数年,远超当前已批准的7天。本综述概述了长期植入式安培酶生物传感器成功部署所面临的诸多挑战,并强调其持续发展中的新兴技术路线。异物反应在...

Controlled release of dexamethasone from subcutaneously-implanted biosensors in pigs: localized anti-inflammatory benefit without systemic effects.

Journal of biomedical materials research. Part A 2010 Ward WK, Hansen JC, Massoud RG, Engle JM 等 6 人

长期植入的生物传感器常在植入后1–2个月因胶原富集包囊形成而灵敏度下降。糖皮质激素可减少胶原沉积,但长期全身给药副作用明显。作者假设极低速率释放强效糖皮质激素地塞米松(dexamethasone, DEX)可在植入部位产生局部抗炎作用而不引起全身效应,并以静脉血清皮质醇水平作为全身暴露指标。研究在猪皮下植入模拟葡萄糖传感器阵列,通过...